The Home Medical Library, Volume 5 (of 6)

Chapter 13

Chapter 132,317 wordsPublic domain

=Ventilation=

=Definition.=--The air within an uninhabited room does not differ from that without. If the room is occupied by one or more individuals, however, then the air in the room soon deteriorates, until the impurities therein reach a certain degree incompatible with health. This is due to the fact that with each breath a certain quantity of CO2, organic impurities, and aqueous vapor is exhaled; and these products of respiration soon surcharge the air until it is rendered impure and unfit for breathing. In order to render the air pure in such a room, and make life possible, it is necessary to change the air by withdrawing the impure, and substituting pure air from the outside. This is _ventilation_.

_Ventilation_, therefore, is the maintenance of the air in a confined space in a condition conducive to health; in other words, "ventilation is the replacing of the impure air in a confined space by pure air from the outside."

=Quantity of Air Required.=--What do we regard as impure air? What is the index of impurity? How much air is required to render pure an air in a given space, in a given time, for a given number of people? How often can the change be safely made, and how? These are the problems of ventilation.

An increase in the quantity of CO2 [carbon dioxide gas], and a proportionate increase of organic impurities, are the results of respiratory vitiation of the air; and it has been agreed to regard the relative quantity of CO2 as the standard of impurity, its increase serving as an index of the condition of the air. The normal quantity of CO2 in the air is 0.04 per cent, or 4 volumes in 10,000; and it has been determined that whenever the CO2 reaches 0.06 per cent, or 6 parts per 10,000, the maximum of air vitiation is reached--a point beyond which the breathing of the air becomes dangerous to health.

We therefore know that an increase of 2 volumes of CO2 in 10,000 of air constitutes the maximum of admissible impurity; the difference between 0.04 per cent and 0.06 per cent. Now, a healthy average adult at rest exhales in one hour 0.6 cubic foot of CO2. Having determined these two factors--the amount of CO2 exhaled in one hour and the maximum of admissible impurity--we can find by dividing 0.6 by 0.0002 (or 0.02 per cent) the number of cubic feet of air needed for one hour,==3,000.

Therefore, a room with a space of 3,000 cubic feet, occupied by one average adult at rest, will not reach its maximum of impurity (that is, the air in such a room will not be in need of a change) before one hour has elapsed.

The relative quantity of fresh air needed will differ for adults at work and at rest, for children, women, etc.; it will also differ according to the illuminant employed, whether oil, candle, gas, etc.--an ordinary 3-foot gas-burner requiring 1,800 cubic feet of air in one hour.

It is not necessary, however, to have 3,000 cubic feet of space for each individual in a room, for the air in the latter can safely be changed at least three times within one hour, thus reducing the air space needed to about 1,000 cubic feet. This change of air or ventilation of a room can be accomplished by mechanical means oftener than three times in an hour, but a natural change of more than three times in an hour will ordinarily create too strong a current of air, and may cause draughts and chills dangerous to health.

In determining the cubic space needed, the height of the room as well as the floor space must be taken into consideration. As a rule the height of a room ought to be in proportion to the floor space, and in ordinary rooms should not exceed fourteen feet, as a height beyond that is of very little advantage.[13]

=Forces of Ventilation.=--We now come to the question of the various modes by which change in the air of a room is possible. Ventilation is natural or artificial according to whether artificial or mechanical devices are or are not used. Natural ventilation is only possible because our buildings and houses, their material and construction, are such that numerous apertures and crevices are left for air to come in; for it is evident that if a room were hermetically air-tight, no natural ventilation would be possible.

The properties of air which render both natural and artificial ventilation possible are diffusion, motion, and gravity. These three forces are the natural agents of ventilation.

There is a constant diffusion of gases taking place in the air; this diffusion takes place even through stone and through brick walls. The more porous the material of which the building is constructed, the more readily does diffusion take place. Dampness, plastering, painting, and papering of walls diminish diffusion, however.

The second force in ventilation is the motion of air or winds. This is the most powerful agent of ventilation, for even a slight, imperceptible wind, traveling about two miles an hour, is capable, when the windows and doors of a room are open, of changing the air of a room 528 times in one hour. Air passes also through brick and stone walls. The objections to winds as a sole mode of ventilation are their inconstancy and irregularity. When the wind is very slight its ventilating influence is very small; on the other hand, when the wind is strong it cannot be utilized as a means of ventilation on account of the air currents being too strong and capable of exerting deleterious effects on health.

The third, the most constant and reliable, and, in fact, principal agent of ventilation is the specific gravity of the air, and the variations in the gravity and consequent pressure which are results of the variations in temperature, humidity, etc. Whenever air is warmer in one place than in another, the warmer air being lighter and the colder air outside being heavier, the latter exerts pressure upon the air in the room, causing the lighter air in the room to escape and be displaced by the heavier air from the outside, thus changing the air in the room. This mode of ventilation is always constant and at work, as the very presence of living beings in the room warms the air therein, thus causing a difference from the outside air and effecting change of air from the outside to the inside of the room.

=Methods of Ventilation.=--The application of these principles of ventilation is said to be accomplished in a natural or an artificial way, according as mechanical means to utilize the forces and properties of air are used or not. But in reality natural ventilation can hardly be said to exist, since dwellings are so constructed as to guard against exposure and changes of temperature, and are usually equipped with numerous appliances for promoting change of air. Windows, doors, fireplaces, chimneys, shafts, courts, etc., are all artificial methods of securing ventilation, although we usually regard them as means of natural ventilation.

=Natural Ventilation.=--The means employed for applying the properties of diffusion are the materials of construction. A porous material being favorable for diffusion, some such material is placed in several places within the wall, thus favoring change of air. Imperfect carpenter work is also a help, as the cracks and openings left are favorable for the escape and entrance of air.

Wind, or the motion of air, is utilized either directly, through windows, doors, and other openings; or indirectly, by producing a partial vacuum in passing over chimneys and shafts, causing suction of the air in them, and the consequent withdrawal of the air from the rooms.

The opening of windows and doors is possible only in warm weather; and as ventilation becomes a problem only in temperate and cold weather, the opening of windows and doors cannot very well be utilized without causing colds, etc. Various methods have therefore been proposed for using windows for the purposes of ventilation without producing forcible currents of air.

The part of the window best fitted for the introduction of air is the space between the two sashes, where they meet. The ingress of air is made possible whenever the lower sash is raised or the upper one is lowered. In order to prevent cold air from without entering through the openings thus made, it has been proposed by Hinkes Bird to fit a block of wood in the lower opening; or else, as in Dr. Keen's arrangement, a piece of paper or cloth is used to cover the space left by the lifting or lowering of either or both sashes. Louvers or inclined panes or parts of these may also be used. Parts or entire window panes are sometimes wholly removed and replaced by tubes or perforated pieces of zinc, so that air may come in through the apertures. Again, apertures for inlets and outlets may be made directly in the walls of the rooms. These openings are filled in with porous bricks or with specially made bricks (like Ellison's conical bricks), or boxes provided with several openings. A very useful apparatus of this kind is the so-called Sheringham valve, which consists of an iron box fitted into the wall, the front of the box facing the room having an iron valve hinged along its lower edge, and so constructed that it can be opened or be closed at will to let a current of air pass upward. Another very good apparatus of this kind is the Tobin ventilator, consisting of horizontal tubes let through the walls, the outer ends open to the air, but the inner ends projecting into the room, where they are joined by vertical tubes carried up five feet or more from the floor, thus allowing the outside air to enter upwardly into the room. This plan is also adapted for filtering and cleaning the incoming air by placing cloth or other material across the lumen of the horizontal tubes to intercept dust, etc. McKinnell's ventilator is also a useful method of ventilation, especially of underground rooms.

To assist the action of winds over the tops of shafts and chimneys, various cowls have been devised. These cowls are arranged so as to help aspirate the air from the tubes and chimneys, and prevent a down draught.

The same inlets and outlets which are made to utilize winds may also be used for the ventilation effected by the motion of air due to difference in the specific gravity of outside and inside air. Any artificial warming of the air in the room, whether by illuminants or by the various methods of heating rooms, will aid in ventilating it, the chimneys acting as powerful means of removal for the warmer air. Various methods have also been proposed for utilizing the chimney, even when no stoves, etc., are connected with it, by placing a gaslight within the chimney to cause an up draught and consequent aspiration of the air of the room through it.

The question of the number, relative size, and position of the inlets and outlets is a very important one, but we can here give only an epitome of the requirements. The inlet and outlet openings should be about twenty-four inches square per head. Inlet openings should be short, easily cleaned, sufficient in number to insure a proper distribution of air; should be protected from heat, provided with valves so as to regulate the inflow of air, and, if possible, should be placed so as to allow the air passing through them to be warmed before entering the room.[14] Outlet openings should be placed near the ceiling, should be straight and smooth, and, if possible, should be heated so as to make the air therein warmer, thus preventing a down draught, as is frequently the case when the outlets become inlets.

=Artificial Ventilation.=--Artificial ventilation is accomplished either by aspirating the air from the building, known as the vacuum or extraction method, or by forcing into the building air from without; this is known as the plenum or propulsion method.

The extraction of the air in a building is done by means of heat, by warming the air in chimneys or special tubes, or by mechanical means with screws or fans run by steam or electricity; these screws or fans revolve and aspirate the air of the rooms, and thus cause pure air to enter.

The propelling method of ventilation is carried out by mechanical means only, air being forced in from the outside by fans, screws, bellows, etc.

Artificial ventilation is applicable only where a large volume of air is needed, and for large spaces, such as theaters, churches, lecture rooms, etc. For the ordinary building the expense for mechanical contrivances is too high.

On the whole, ventilation without complex and cumbersome mechanisms is to be preferred.[15]

FOOTNOTES:

[13] In cerebro-spinal meningitis, tuberculosis, and pneumonia, fresh air is curative. Any person, sick or well, cannot have too much fresh air. The windows of sleeping rooms should always be kept open at night.--EDITOR.

[14] These outlets may be placed close to a chimney or heating pipes. Warm air rises and thus will be forced out, allowing cool fresh air to enter at the inlets.--EDITOR.

[15] The ordinary dwelling house needs no artificial methods of ventilation. The opening and closing of windows will supply all necessary regulation in this regard. The temperature of living rooms should be kept, in general, at 70 deg. F. Almost all rooms for the sick are unfortunately overheated. Cool, fresh air is one of the most potent means of curing disease. Overheated rooms are a menace to health.--EDITOR.